KANEKA KanCapA™ 3G Protein A Mix-N-Go™ (F950),Cygnus代理


Product Information

产品类型:
ELISA Kit

保存温度:
All kit reagents 2°C to 8°C

规格:
96 Well Plate

Time to result:
~1 hr. 45 min

LOD:
~20 pg/mL

LLOQ:
~0.16 ng/mL

推荐的稀释剂:
I600

支持文档

Request a Qualification summary
Request a Certificate of Analysis

STANDARDS SDS

MIX-N-GO DENATURING BUFFER SDS – F604

DILUENTS SDS

MICROTITER PLATE SDS

STOP SOLUTION SDS – F006

WASH CONCENTRATE SDS – F004

TMB SUBSTRATE SDS

Protein A, Mix-N-Go™ ELISA Kits – The Gold Standard in Residual Protein A Impurity Analysis

上海金畔生物科技有限公司作为Cygnus在中国地区的代理商,全面提供Cygnus的各种宿主蛋白检测和工艺污染物残留检测试剂盒,部分产品在国内有大量现货。上海金畔生物科技有限公司不仅代理Cygnus的产品,在生物制药领域,上海金畔生物科技有限公司还可提供美国Kerry公司的细胞大规模培养所需的血清替代物,如植物蛋白胨(HyPep1510、HyPep4601N、HyPep7504、HySoy)、酵母粉以及成分明确添加物(重组白蛋白、重组抑肽酶、重组胰岛素)、冻干保护剂NZ Amine AS;Pfanstiehl注射级海藻糖、半乳糖等。欢迎致电上海金畔生物科技有限公司021-50837765了解更多产品信息。

PowerUpSYBRGreenMasterMix货号A25742

PowerUp SYBR Green Master Mix

货号

A25742

品牌

ABI

产品线

BID
  • 商品详情

PowerUp™ SYBR™ Green Master Mix描述

PowerUp™ SYBR® Green Master Mix is a pre-formulated, optimized, universal 2X master mix for real-time PCR workflows. Coupled with user-supplied primer sets and template, PowerUp™ SYBR® Green Master Mix is designed to amplifiy targets for accurate gene expression analysis.PowerUp™ SYBR® Green Master Mix features include:• A dual hot-start mechanism for excellent specificity• Highly reproducible CTs over a broad dynamic range• Inclusion of UDG to help prevent carryover contamination• Stability of pre-assembled reactions for up to 72 hours• Compatibility with most real-time qPCR instrumentsExceptional specificity with dual hot-start mechanismSpecificity is paramount in obtaining high-quality data in SYBR® Green reactions and can be enhanced through control of the Taq DNA polymerase at lower temperatures before stringent primer binding. PowerUp™ SYBR® Green Master Mix uses the Dual-Lock™ Taq DNA polymerase enzyme that combines two unique hot-start mechanisms to help control its activity and to prevent undesirable early activity of the polymerase at low temperatures. In an experiment evaluating 24 different primer sets, PowerUp™ SYBR® Green Master Mix generated single melt curves 100% of the time, consistent with highly specific amplification.

Tight reproducibility in CTs over a wide dynamic rangePowerUp™ SYBR® Green Master Mix demonstrates excellent reproducibility over a wide dynamic range for a variety of targets tested (see figure). In addition, this master mix provides efficient amplification over 6 logs of sample input. Unlike competitor mixes that can exhibit inhibition at high cDNA inputs and low correlation coefficients over a dynamic range experiment, PowerUp™ SYBR® Green Master Mix efficiency is maintained over the full dynamic range to help deliver maximal confidence in data quality (see figure).UDG included for carryover contamination controlThe inclusion of uracil-DNA glycosylase (UDG) and dUTP in the PowerUp™ SYBR® Green Master Mix enables the degradation of any previously amplified PCR products, helping prevent contamination of subsequent qPCR reactions and possible false positives.Stability of pre-assembled reactionsThe tight control of the Dual-Lock™ Taq DNA polymerase in PowerUp™ SYBR® Green Master Mix enables reactions to be assembled up to 72 hours prior to cycling without impacting data (see figure). This consistency allows users to have confidence and flexibility in the use of PowerUP™ SYBR® Green Master Mix across numerous workflow scenarios1.

Broad instrument compatibilityPowerUp™ SYBR® Green Master Mix can be used in either standard or fast cycling mode and is compatible with all Applied Biosystems® real-time PCR instruments2. It is also compatible with the Bio-Rad IQ™5 and CFX96™ / CFX384™ systems, Roche LightCycler® LC480, and Stratagene® MX3005P® systems. For optimal results, recommended primer concentrations are 300–800 nM.Learn more about PowerUp™ SYBR® Green Master Mix >1Pre-PCR stability is influenced not only by the master mix, but also by the target being analyzed. For maximum confidence, researchers should confirm stability profiles of their specific targets.2For optimal performance, standard cycling using the Applied Biosystems® 7900 system is recommended.